Hormann garage door remote control unit as part of the Smart Home system via a KNX bus with the ability to connect various remote garage gas sensors. It is installed on a DIN rail, wall, ceiling.
A remote control unit for Hormann garage door drives via a KNX bus with the ability to connect various remote sensors for garage gas pollution and monitoring exceeding limit values. It is installed on a DIN rail, wall, ceiling.
Compatible Hörmann drives:
| Drive | Note | The position of the “Series” switch |
|---|---|---|
| ProMatic 4 / SupraMatic 4 | 4 | |
| Liftronic 700-2 / Liftronic 800-2 | ||
| ProMatic 3 / Liftronic 500 | not supported | |
| SupraMatic 3 / SupraMatic HT3 1 | The serial number ends in “D”, “E”, “F” | 3 |
| LineaMatic / LineaMatic 2 | ||
| RotaMatic / RotaMatic 2 | ||
| VersaMatic | ||
| WA 300 R S4 / WA 300 S4 |
Specifications
- Transmitting the gate status to the KNX bus
- Opening, closing, switching to ventilation mode
- Control of gates that are forgotten for a long time in the open position
- Sound notification of various emergency situations
- Connection of up to 2 garage gas sensors (exhaust gases, methane, propane, carbon dioxide)
- Monitoring of excess gas content in the room (if sensors are connected)
- The possibility of switching to ventilation mode when the maximum gas concentration is reached (if there is an appropriate sensor).
- The function of cold reset of the 4th series drives in case of loss of communication (for example, after downloading the ETS application)
- Accessories for garage door drives: Hörmann
Accessories for garage door drives: Hörmann:
| Article number | HMN-F0100-1 |
| The KNX interface | |
| Specification | TP-256 |
| Connecting to the bus | The WAGO connector 243-211 |
| The device is powered | by the KNX bus, from the gate drive |
| KNX bus consumption (29V DC) | <2mA |
| Consumption from gate drive (24 V DC) | <50mA |
| Physical characteristics | |
| Operating temperature range | from 0 to +45°C |
| Humidity during operation | from 5 to 95% (non-condensing) |
| Fire resistance class | UL94 V0 (does not support gorenje) |
| Degree of protection of the housing | IP20, in a clean environment |
| DIN rail mounting type | (EN50022) in an electrical cabinet |
| Size | 37x91x61mm (37x107x61) |
| Weight | 100g |
| Configuration program | ETS 5/6 (RU/EN) |
Device description: Datasheet-HMN-F0100-1-RU.PDF
Instructions: Manual-HMN-F0100-1-RU.PDF
Application program ETS5/6 EN/RUS. Version 1.2 Download
Visio Element Library Download
Connection diagram of sensors and interface Download